Comfort CT200

The Comfort CT200 is for anyone who wants ventilation with highly efficient heat recovery.

Comfort CT200's compact design makes it ideal to use in new and refurbished flats, terraced housing and summer cottages, where the space available is limited and easy fitting is required. The system can be fitted to the ceiling or the wall.

The system extract hot, humid air from e.g. the kitchen, bathroom and utility room, and at the same time remove dust particles, moisture and odours from the home. Furthermore, the energy from the extract air is used to heat the incoming air.

The system can be equipped with supplementary heating coils that can be connected to an electric or central heating system. The systems will produce a comfortable incoming air temperature even in the coldest winter weather. When you buy a Comfort system, you get a comfortable and healthy indoor climate and cost savings on your heating bill.

Comfort CT200 is an energy-efficient ventilation system with heat recovery for homes with a ventilation requirement of up to 200 m3/h. Comfort CT200 is particularly suitable for newly-built or renovated flats, terraced houses and summer cottages where the space is limited.

Comfort CT200 is designed for vertical or horizontal mounting, which ensures flexible installation.

Comfort CT200 is factory tested and ready for use. Installation and commissioning must be performed by an authorised electrician.

Dimensions (WxDxH) 1040 × 535 × 338 mm (*1)
Weight 30 kg
Plate type casing Aluzinc steel plate
Heat exchanger type Polyethylenterephthalat counter flow heat exchanger with aluminium casing
Fan type EC, constant rotation
Filter class Standard ISO Coarse >90% (G4)
Duct connections Ø 125 mm
Condensate drain PVC, Ø 20 × 1,5 mm
Supply voltage 230 V (±10 %), 50/60 HZ
Max. input/power 53 W / 0,25 A
Tightness class IP31
Standby power 3,4 W
Ambient temperature -20/+40 °C
Heat loss 0,96 W/m2K (*3)
Heat loss classification T2

Ecodesign/ERP data

Fan data
Motordata (optimalt driftspunkt)

Spacing bracket, vertical installation

For vertical installation, a wall bracket can be attached to lead and conceal the ducts. This converts the unit to a top unit.

The side panels are prepared for mounting of the display panel.

Pollen filter ISO ePM1 65-80% (F7)

A pollen filter class ISO ePM1 65-80% (F7) can be fitted in the unit. The pollen filter is fitted with the ISO Coarse >90% (G4) plate filter.

DBTU damper

If there is not enough space to fit an EM-box, Nilan offers a DTBU damper, which can be fitted between kitchen and bathroom. The damper functions precisely like the EM-box but requires longer cables.

Noise-attenuating flexible hose

For easy fitting and excellent noise attenuation between the system and the distribution box and/or between the system and roof vents.

Project model

Can be supplied with all connectors leading from the housing. This solution makes it easier to connect external components, such as range hood, damper and Modbus.

User selection/Range hood solution

It is also possible to activate user selection mode (Step 4) via a potential-free contact. The set includes a cable with two RJ12 connectors.
Connect the connector at the unit and connect the control panel and the 10 m of cable, for example, to a range hood, ind the two-connectionbox.

User selection/range hood-damper solution

It is also possible to activate user selection mode (Step 4) via a potential-free contact. The set includes an RJ12 cable, a connection box for the range hood, damper connections as well as a 230V main supply plug.

Electrical heating element incl. regulation

When you fit an electrical heating surface, you can raise the fresh air temperature to the desired level at any time. The electrical heating surface is supplied ready to fit into the fresh air duct and, for easy fitting, the device is pre-fitted with all the required sensors.

 

Electrical pre-heating element (Frost protection)

An electrical pre-heating element heats up the outdoor air before it enters the unit. This avoids having to defrost the unit, resulting in a loss of power.

There are temperature sensors supplied to be fitted in the ducts.

Expansion PCB

The expansion PCB provides additional functions for the CTS 602 control unit.

Water heating element incl. regulation (duct mounted)

The supply temperature can always be raised to the required level using a water heating element. The water heating element is designed to be built into the duct and must be connected to the primary heating supply. Supplied with two-way adjustment valve, temperature sensor and frost thermostat (expansion PCB required).

 

Water trap

The water trap makes sure that condensate water runs freely from the unit.

 

Data sheet
Comfort CT200 data sheet

Brochure
Ventilation and indoor climate solutions

Data sheet accessories
Heating elements

DWG Drawings
Comfort CT200 DWG file

3D files
Comfort CT200 (left) 3D file
Comfort CT200 (right) 3D file

If you want to convert STEP files to Revit, do the following:
Import the STEP file to Autocad, export it as a 3D DWG file and then import the file into Revit.

Installation instructions
Comfort CT200 with CTS150 control

Comfort CT200 with CTS602 control HMI Touch panel

User manual
Comfort CT200 with CTS150 control

Comfort CT200 with CTS602 control HMI Touch panel

Software manual
Comfort CT200 with CTS602 control HMI Touch panel

CTS602 Modbusprotokol

SEC* average climate - 41.5 kWh/(m2.a)
SEC* cold climate - 80.7 kWh/(m2.a)
SEC* warm climate - 16.4 kWh/(m2.a)
SEC-Class A
Type Two-way ventilation unit for residential
Type of drive Variable speed drive
Type of heat recovery system Recuperative
(counterflow heat exchanger)
Thermal efficiency
of heat recovery
91.3 %
Maximum flow rate 200 m3/h (100 Pa)
Electric power input of fan drive, including any motor control equipment, at maximum flow rate 70.0 W
Sound power level (LWA) 49 dB(A)
Reference flow rate 0.039 m3/s (140 m3/h)
Reference pressure difference 50 Pa
SPI 0.209 W/(m3/h)
Central demand control 0.85
Maximum internal leakage 0.19 %
Maximum external leakage 0.35 %
Visual filter warning An alarm on the user panel appears when filters need changing.
To maintain the performance and energy efficiency of the unit it is very important to change filters regularly.
Disassembly instructions www.nilan.dk

* Specific energy consumption

 

AEC - annual electricity consumption 235 kWh/year (100 m2)
AHS** average climate 4665 kWh (100 m2)
AHS** cold climate 9126 kWh (100 m2)
AHS** warm climate 2109 kWh (100 m2)

** Annual heating saved

Capacity

Capacity of standard unit as a function of qv and Pt, ext.

SEL values according to EN 13141-7 are for standard units with standard filters ISO Coarse >90% (G4) and without heating element.

SEL values comprise the unit´s total power comsumption excl. control.

Conversion factor: J/m3 : 3600 = W/m3/h

Attention! The SEL values are measured and stated as a total value for both fans.

Temperature efficiency

Temperature efficiency for units with counterflow heat exchanger according to EN308 (dry).

Temperature efficiency EN308:
ɳt = (tsupply air-tfresh air)/(textract air-tfresh air)

Sound data

Sound data for qV = 126 m3/h and Pt, ext = 75 Pa according to EN 9614-2 for surfaces and EN 5136 for ducts.

Sound output level LWA drops with falling air volume and falling back pressure.

Sound output level LpA at a given distance will depend on acoustic conditions in the place of installation.

Connections
1: Fresh air
2: Supply air
3: Extract air
4: Discharge air
5: Condensation drain

CTS150 control unit

The CTS150 control unit is a simple control unit used to control the CT200 system. It offers the user only limited access to settings.

Users can adjust the air volume and humidity levels.

The control unit also shows whether the system is working and when an alarm is triggered.

To set and regulate the system, it has to be connected to a PC via a USB flash drive. Download the software from NilanNet and install. The software can be used not only to set the system, but also to read operating data.
 

CTS602 control unit

The Comfort CT200 is controlled using its CTS 602 HMI touch panel, featuring a wide range of functions, e.g., menu-controlled operation, weekly programme settings, filter monitor with timer, fan speed adjustment, summer bypass (free cooling), post-heating element control, error messages etc.

The CTS 602 comes with factory settings, including a default setting which can be customised to operational requirements to achieve optimum operation and utilisation of the system.

There is an option for selecting between 2 front page images for the main screen.

Operating instructions for the CTS 602 can be found in a separate user manual supplied with the unit.

 

Connections
1: Fresh air
2: Supply air
3: Extract air
4: Discharge air
5: Condensate drain
6: Electric and water heating

Automation
T2/T7: Supply air sensor
T9: Heating element
T3: Extract air sensor
T4: Discharge air and defrost sensor
T8: Fresh air sensor
 

Functional overview CTS150 control

Functional overview  

 +Standard 

-Accessories

Filter monitor Filter monitor with timer (factory setting of 90 days). Adjustable to 30/90/180/360 days.  +
100 % bypass Bypassing the outdoor air reduces heat recovery when heat recovery are not needed.  +
Humidity control Allows you to set a higher or lower ventilation step in the case of high/low air humidity.  +
Summer/Winter operation Possible to set operation for summer and winter. +
Winter low Allows you to select a low ventilation step in the case of low outside temperatures.  +
Defrost function Temperature-based automatic function for defrosting the heat exchanger.  
Temperature control The system’s overriding temperature sensor is T3 extract air.  +
Air volume Allows you to set four ventilation steps stepless. Supply air and extract air are set individually.
Step 1 < 25% - Step 2 < 45% - Step 3 < 70% - Step 4 < 100%
 +
User option It is also possible to activate user selection mode (Step 4) via a potential-free contact.  -

 

Functional overview CTS 602 control

Functional overview  

 +Standard 

-Accessories

3 levels The control function is divided into 3 levels: User/Service/Factory with various options at each level.  +
Weekly plan The unit has 3 weekly programmes (with a factory setting of “off”)
• Programme 1: for working families
• Programme 2: for stay-at-home families
• Programme 3: for businesses
There is also an option for you to set your own weekly programme.
 +
User option
1 & 2
This allows you to override the operating mode in the main menu via an external potential-free contact or PIR sensor.  +
Alarms Alarm log featuring the last 16 alarms.  +
Datalog Possible to log data. Kapacity 46.000 logs
• Adjustable between 1 and 120 minutes
• If “OFF”, only events and alarms are logged
+
Filter monitor Filter monitor with timer (factory setting of 90 days). Adjustable to 30/90/180/360 days.  +

Bypass     

Bypassing the outdoor air reduces heat recovery when heat recovery are not needed.  +
Air quality Allows you to choose whether to switch humidity sensors and/or CO2 sensors on and off.  +/-
Humidity control Allows you to set a higher or lower ventilation step in the case of high/low air humidity.  +
Summer/Winter operation Possible to set operation for summer and winter.  
Winter low Allows you to select a low ventilation step in the case of low outside temperatures.  +
Defrost function Temperature-based automatic function for defrosting the heat exchanger.  +
Frostprotection In case of failing heating system, the unit is turned off to avoid further cooling with a risk of the water heating coil frost bursting.  +
Temperature control Allows you to select the temperature sensor which will control the unit.
• T3 EXHAUST (extract air)
 +
Room low Stops the unit at a low room temperature. Hereby is cooling of the home avoided in case of a failing central heating system. Standard set to OFF. Can be set from 1 to 20 degrees and is controlled by:
• T3 EXHAUST (extract air)
 +
Air volume Allows you to set four ventilation steps stepless. Supply air and extract air are set individually.
Step 1 < 25% - Step 2 < 45% - Step 3 < 70% - Step 4 < 100%
 +
External firealarm Possible to connect the unit to external firealarm. +
Joint alarm Outlet for joint alarm.  -
Constant pressure control Allows control from both the extract air and supply air side.  +
Cooling Via bypass (can only cool with outdoor temperature) and cool recovery (can only cool with indoor temperature).
This allows you to choose whether to run the system at a higher or the highest ventilation step during cooling.
The weekly programme has an option for setting cooling at night.
 +
Intake air control Allows you to set the regulator to control the intake air temperature/supply air
(only available if the control unit has been configured for a supply-heating element).
 -
External water heating element • Temperature sensor T7 is an supply air sensor
• Integrated frost protection for external water heating element
• Motorised valve and circulation pump control unit
 +
External electric heating element • Temperature sensor T7 is an supply air sensor
• Overheating protection
 +
Delayed start-up There is a possibility for a delayed start-up by the fans, when a closing damper is installed.  +
Reset Allows you to restore the factory settings.  +
Manual test Allows you to test the unit’s functions manually. +
Language Option for setting the relevant language (Danish/Finnish/Norwegian/Swedish/German/English/French/Polish). +

 